S&A CW-6260BN Industrial Water Chiller (3.64HP, AC 1P 220V 60HZ) for CO2 Laser Cutter
  • S&A CW-6260BN Industrial Water Chiller (3.64HP, AC 1P 220V 60HZ) for CO2 Laser Cutter

See larger image and other views (with zoom)

S&A CW-6260BN Industrial Water Chiller (3.64HP, AC 1P 220V 60HZ) for CO2 Laser Cutter

 

รหัสสินค้า:CW-6260BN

  • ราคา Unit : ฿ 95,629/set   (ขอส่วนลดพิเศษ) (สินค้าถึงภายใน 25-45 วัน)

  • จำนวน: set(s) Total Cost: ฿95,629
  • น้ำหนักการส่ง: 333.8lb (151.73kg) freightขนส่งสินค้า

  • Submit your order online to get membership points, a proforma invoice will be sent to you after you submit the order.
    Add to  Cart

Buyer Protection

CAUTIONS

We are authorized as "S&A" brand name product agent.
All of S&A water chillers are certified with design patent. Counterfeiting is not allowed, 
Please recognize S&A logo when you purchase S&A water chillers.


Description

Laser chiller CW-6260 is the highly recommended option for cooling 400W industrial CO2 laser cutter. It is designed with a durable and reliable compressor, ensuring stable cooling performance for the laser. The controllable temperature range is 5°C to 35°C with constant temperature mode and intelligent temperature control mode available to choose from. What makes the intelligent temperature control mode special is that it enables automatic water temperature adjustment, setting users’ hands free. This laser water chiller is CE, RoHS and REACH certified and packed in durable materials. Suitable fluid would be purified water, distilled water and deionised water.

Features:
  • Cooling Capacity: 8kW
  • Active cooling
  • Temperature stability: ±0.5℃
  • Temperature control range: 5°C ~35°C
  • Refrigerant: R-410a
  • Intelligent temperature controller
  • Multiple alarm functions
  • Ready for immediate use
  • Easy maintenance and mobility
  • Visual water level

SPECIFICATION


Tips: Cooling water additive is forbidden by express company, so we could not put it into the package.You can buy it from local.

Model

 CW-6260BN

Voltage

AC 1P 220V

Frequency

60Hz

Current

3.9~21.1A

Machine Power

4.4kW

Compressor Power

2.72kW

3.64HP

Nominal cooling capacity

28115Btu/h

8.24kW

7085Kcal/h

Refrigerant Charge

1050g

Refrigerant

R-410a

Pump Power

0.75kW

Max. lift

53M

Max. flow

70L/min

Precision

±0.5℃

Reducer

Capillary

Tank Capacity

22L

Inlet and Outlet

Rp1"

N.W

95Kgs(209.4lb)

G.W

111Kgs(244.7lb)

Product Dimension

30.3" x 21.7" x 40.6" (770 x 550 x 1030mm)

Package Dimension

33.5" x 29.5" x 46.9" (850 x 750 x 1190mm)

CONTOUR AND PARTS INTRODUCTION
Intelligent temperature controller
The temperature controller offers high precision temperature control of ±0.5°C and two user-adjustable temperature control modes - constant temperature mode and intelligent control mode.

Easy-to-read water level indicator
The water level indicator has 3 color areas - yellow, green and red.
Yellow area - high water level.
Green area - normal water level.
Red area - low water level.

Caster wheels for easy mobility
Four caster wheels offer easy mobility and unmatched flexibility.

Ventilation Distance

Certificate

 

Warehouse

Test System

Packing

 

Installation

Open the package to check if the machine is intact and all the necessary accessories are completed.

 

Open the injection port to feed cooling water. (Do not let the water spill over!)

 
Observing the water level gauge and adding water slowly, be careful not to have the water overflowed! For the cooling of carbon steel equipment, the water should be added an appropriate amount of cooling water additive (anti-corrosion water aqua). Working in cold north area, it’s better to use noncorrosive antifreeze fluid.

According to system conditions, please connect the water inlet and outlet pipe well.

 

Plug in power, turn on the power switch. (Do not start up without water in the water tank!)

 
(1) Power switch turned on, the circulation pump of the chiller starts working. The first time of operating may cause more bubbles in the pipe leading to a flow alarming occasionally, but running for a few minutes later, it will go back to normal.
(2) After the first boot, you must immediately check whether the water pipe leaks.
(3) Power switched on, if the water temperature is below the set value, it is normal that fans and other components of the machine do not work. The temperature controller will automatically control the working conditions of the compressor, magnetic valve, fans and other parts based on the set controlling parameters.
(4) As it takes a longer time to start over the compressor and other components, according to different conditions, the time is range from seconds to minutes, so do not turn off the power and again on frequently.

Check the water level in the water tank.

 
The first startup of the new chiller empties the air in the water pipe, leading a slight water level decline, but in order to keep the water level in the green area, it’s allowed to add adequate water again. Please observe and record the current water level, and inspect it again after the chiller running for a period of time, if the water level drops obviously, please re-inspect the water pipeline leakage.

Adjust parameters of temperature controller.

 
CW-6200 series use an intelligent thermostat. Normally users do not need to adjust it. If it is really necessary, please refer to page 17, “Operating status and parameters adjustment.”

 

Cautions

Please ensure that the power supply and electrical outlet are in good contact and the earth wire must be firmly grounded!

 

Please make sure there is stable and normal voltage for the working chiller!

 
As the refrigeration compressor is more sensitive to the power supply and voltage, so the operating voltage of our standard product is of 210 ~ 240V (110V model is of 100 ~120V). If you do need a wider operating voltage range, customization is available for us.

Unmatched power frequency can cause the chiller damage!

 
Please choose model of 50Hz or 60Hz according to actual circumstance.

To protect the pump, it’s strictly forbidden to run the chiller without water in the storage water tank!

 
The new machine is packed after draining whole water in the tank, so please make sure the tank has water inside before machine starting, otherwise it’s easily to have the pump damaged. When the water level is below the green (NORMAL) range of the water level gauge, the cooling capacity of our chiller will go down slightly. Hence please ensure the water level is within the green (NORMAL) range. To drain through circulating pump is strictly prohibited!

Please be sure that the air inlet and air outlet are in good ventilation!

 
There must be at least 30cm from obstructions to the air outlet which is in the back of the cooler, and should leave at least 8cm between obstructions and the side air inlet.

The filter screen must be regularly cleaned!

 
It’s essential to unpick and wash the dust gauze, or the serious blockage will cause breakdown to the chiller.

Please pay attention to the effect of the condensate water!

 
With greater ambient humidity, when the water temperature is lower than the ambient temperature, the condensate water will generate on the surface of water circular pipes and the cooled components. If above circumstance appears, it is recommended to set a higher water temperature or keep pipes and cooled parts warm.

Professional use only!

 
The appliance is not to be used by children or persons with reduced physical,sensory or mental capabilities, or lack of experience and knowledge,unless they have been given supervision or instruction,children being supervised not to play with the appliance!

 

Troubleshooting

Failure Failure Cause Approach
Machine turned on but unelectrified
Power cord is not plugged in place Check and ensure the power interface and the power plug is plugged in place and in good contact.
Fuse burnt-out Replace the protective tube in the power socket on the back of chiller.
Flow Alarm (controller displays E6)use a water pipe directly connect to the water outlet and inlet but still without water flowing Water level in the storage water tank is too low Check the water level gauge display, add water until the level shown in the green area; And check whether water circulation pipe leaks.
Flow Alarm occurs while running with other equipment (controller displays E6),but there is water flowing and no alarm whten use a water pipe directly connected to the chiller water outlet and inlet. Water circulation pipes are blocked or a pipe bending deformation. Check water circulation pipe
Ultra-high temperature alarm (controller displays E2)
Blocked dust gauze, bad thermolysis Unpick and wash the dust gauze regularly
Poor ventilation for air outlet and inlet To ensure a smooth ventilation for air outlet and inlet
Voltage is extremely low or astable To improve the power supply circuit or use a voltage regulator
Improper parameter settings on thermostat To reset controlling parameters or restore factory settings
Switch the power frequently To ensure there is sufficient time for refrigeration (more than 5 minuets)
Excessive heat load Reduce the heat load or use other model with larger cooling capacity
Ultrahigh room temperature alarm (controller displays E1) The working ambient temperature is too high for the chiller To improve the ventilation to guarantee that the machine is running under 40℃.
Serious problem of condensate water Water temperature is much lower than ambient temperature, with high humidity Increase water temperature or to preserve heat for pipeline
Water drains slowly from outfall during water changing Water supply inlet is not open Open the water supply inlet
  • ทั้งหมด
  • คำแนะนำ
  • รายละเอียดสินค้า
  • การส่งสินค้า
  • การชำระเงิน
  • อื่น ๆ
ถามคำถาม

เลือกหัวข้อ:

รายละเอียดสินค้า การส่งสินค้า การชำระเงิน อื่น ๆ


Content:


แนบไฟล์:

Preview Size State Operation


รหัสยืนยัน:

การส่งสินค้า :
We ship to more than 200 countries and 300 ports worldwide!
By Express: 3-5 business days
By Sea: 20-60 business days
How much to ship to
my place?
การชำระเงิน:
T/T Bank Transfer:
:
:

Video Guide:

เข้าสู่ระบบ E-mail สำหรับข้อเสนอพิเศษ

อัพเดท ส่วนลด ข้อเสนอพิเศษ รายการฟรี และ รางวัลเงินสด

หาข้อมูลเพิ่มเติม>>

ดูโปรโมชั่นของเราในสัปดาห์นี้.

www.Sign-in-Thai.com, It is the biggest online supplier of sign products in Thailand and specialized in providing One Stop Solution for customers to select AD equipments, AD consuming materials, sign exhibition products, etc. We have set up overseas branches in 6 foreign countries in order to provide better service for our customers all over the world. Our products cover all field of the AD and signage and all the products we supply are made in accordance with international quality standards as a result that, at present, we have more than 9,000 products online for sale. Since we implement the centralized purchasing, all the products are quoted with competitive prices and good quality.